Skip to main content

An official website of the United States government

You have 2 new alerts

6515--WCHCS New Medgas Systems Replacement

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Sep 17, 2024 10:59 am MDT
  • Original Published Date: Aug 29, 2024 08:49 am MDT
  • Updated Date Offers Due: Sep 20, 2024 03:00 pm MDT
  • Original Date Offers Due: Sep 13, 2024 03:00 pm MDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Oct 05, 2024
  • Original Inactive Date: Oct 13, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 339112 - Surgical and Medical Instrument Manufacturing
  • Place of Performance:
    Grand Junction VA Medical Center Grand Junction , 81501
    USA

Description

Can you provide a copy of your most recent Annual Medical Gas Inspection report? See attachments Can you provide floor plans showing the equipment and master alarm panel locations? See attachments Can you provide pictures of the current Master Alarm Panels? There should be a minimum of two per NFPA 99 requirements. See photos Are the following functions monitored on both Master Alarm Panels for the Medical Air and Medical Vacuum systems being replaced? This is required per NFPA 99 5.1.9.2 and system Verification under NFPA 99 5.1.12.4.5.2 a. Medical Air Line Pressure Low b. Medical Air Line Pressure High c. Medical Air Dew Point High d. Medical Air Lag Compressor In Use, CO Level High (These can be 1 alarm) e. Medical Vacuum Line Pressure Low f. Medical Vacuum Lag Pump In Use See photos What floor is the mechanical room(s) located on for the Medical Air and Medical Vacuum systems? Med Vac Third floor Med Air Basement Will the systems have to be disassembled to be transported to the mechanical room(s)? Unknown Is there a loading dock at the building where the systems are being installed? The VA has a loading dock Is there an identified path from the receiving area to the mechanical room(s) and will there be any challenges getting the equipment there? Unknown Will there be temporary systems required or a back feed? No back feed will have to divert What is the size of the existing housekeeping pad for the Medical Vacuum System? 96 x 76 What is the material of the existing medical vacuum pump exhaust piping? Copper What is the size of the existing medical vacuum exhaust piping? 3 1/8 O.D. Where does the medical vacuum exhaust piping exit the building? Third floor roof Is the medical vacuum exhaust turned down/screened? N/a Is the medical vacuum exhaust 10 from windows/doors and 25 from air intakes? N/a Is the existing medical vacuum exhaust brazed or soldered? N/a What is the size of the Medical Vacuum distribution piping? See attachments What is the size of the existing Medical Air intake? 3 Is the existing Medical Air intake brazed? N/a Where does the Medical Air intake exit the building? N/a Is the Medical Air intake at least 25 from exhausts, 10 from operable doors and windows, and 20 off the ground? N/a Is the Medical Air system required to be put on a housekeeping pad? Please install a housekeeping pad Are the mechanical spaces temperature-controlled? Not exactly Does the facility have an electrical contractor that is familiar with the facility? Please provide contact information. Hawk Contracting Group is familiar with the facility

Contact Information

Contracting Office Address

  • 6162 S WILLOW DR SUITE 300
  • Greenwood Village , CO 80111
  • USA

Primary Point of Contact

Secondary Point of Contact





History