Skip to main content

An official website of the United States government

You have 2 new alerts

Z1AA--CON | 564-22-107 | B4 REPLACE FAN COIL UNITS | Project 564-22-107

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Mar 22, 2022 03:58 pm CDT
  • Original Response Date: Mar 29, 2022 02:00 pm CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jun 27, 2022
  • Initiative:
    • None

Classification

  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: Z1AA - MAINTENANCE OF OFFICE BUILDINGS
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    DEPARTMENT OF VETERANS AFFAIRS VETERANS HEALTHCARE SYSTEM OF THE OZARKS Fayetteville , AR 72703
    USA

Description

Page 3 of 3 Released pursuant to Federal Acquisition Regulation (FAR) Part 10: Market Research, this is a Request for Information. Purpose: Veterans Health Care System of the Ozarks | Replace B4 Fan Coil Units | Project# 564-22-107 In an effort to enhance opportunities for Service Disabled Veteran Owned Small Businesses (SDVOSB) as required by Public Law 109-461, specifically the Veterans First Contracting Program, NCO16 is performing preliminary market research to identify interested, qualified, capable, SDVOSB and VOSB firms possessing the capacity necessary to compete for a VHA procurement opportunity. In case no SDVOSBs or VOSBs possess the capacity, all Small Businesses possessing the necessary capacity are encouraged to provide a response. Results of the preliminary market research will be used to determine the potential future solicitation s set-aside requirement. This source sought notice is issued solely for informational, market research, and planning purposes. It does not constitute an Invitation for Bid (IFB), Request for Quote (RFQ), Request for Proposal, or a promise to issue a subsequent RFQ/IFB/RFP. At this time, no solicitation document exists. Issuance of this notice does not establish any obligation on the part of the Government, and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. In addition, respondents are advised that the United States Government is under no obligation to pay for any information or administrative cost incurred in response to this notice. At this time, proprietary information is not being requested. Respondents shall refrain from including proprietary information in responses to this notice. The Department of Veterans Affairs anticipates awarding a one-time, Firm-Fixed Price (FFP) Contract. Project Scope Summary: The Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, parts, and related services in accordance with the Statement of Work (SOW), drawings, specifications, Federal Acquisition Regulation (FAR), and VA Acquisition Regulation (VAAR) to remove and replace existing Heating Ventilation and Air Conditioning (HVAC) systems which has surpassed its useful service life including, but not limited to, 4-pipe fan coil units (FCUs), hydronic pumps, condensate receiver tank and pumps, pneumatic control system (replace with direct digital control system), hydronic and steam piping (including associated fittings, valves, insulation, gauges, thermometers, sensors, utility meters, hangers, supports, and traps), trap meters, HVAC water treatment, and adjacent building finishes and trim in Building 4 of the Veterans Healthcare System of the Ozarks located at 1100 N. College Avenue in Fayetteville, AR. VAAR 836.204| Disclosure of the magnitude of construction projects. Between $1,000,000 and $5,000,000. Requested Information: 1. Please provide a positive statement of interest in submitting a quote based on the general scope of work description. 2. Please identify your firm s small business category. If your firm is either SDVOSB or VOSB, please state whether you are currently certified by the Department of Veterans Affairs Center for Veterans Enterprise (CVE) based upon North American Industry Classification System code (NAICS) 238220 Plumbing, Heating, and Air-Conditioning Contractors. Current SBA size standard for NAICS 238220 is $16.5M. 3. Please provide a capability statement. Describe your firm s in-house capability to accomplish the summarized project scope/goal; how your firm intends to meet the 15% self-performance requirement per PL109-461; and confirmation that your firm can obtain performance and payment bonds for this project. 4. Please state your firm's name, address, DUNS and CAGE number, and primary point of contact, including telephone number(s) and email address. 5. Please provide the following information for your three most relative, recent projects: (a) Contracting agency address and contracting officer s name, email address, and telephone number. (b) Contract number, date, amount of award, and date of completion. (c) Was your company the prime or a subcontractor? If performance was as a subcontractor, please provide the prime company s business name, address, email address, and telephone number, as well as the name, email address and telephone number of a specific contact person. (d) Describe items/services provided under the contract. (e) Please state if there were any performance issues under the contract resulting in the issuance of a Cure Notice or Show Cause Notice by the Contracting Officer. Response Submission: Please submit your information via email to Felicia Lovelady, Contract Specialist, at Felicia.Lovelady@va.gov, by the closing date and time listed. Please limit your responses to three (3) pages and please include the following as the subject line of your email: 564-22-107| Replace B4 Fan Coil Units | SOURCES SOUGHT RESPONSE Please do not include advertising or promotional materials. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Contact Information

Contracting Office Address

  • 715 SOUTH PEAR ORCHARD RD., PLAZA 1
  • RIDGELAND , MS 39157
  • USA

Primary Point of Contact

Secondary Point of Contact





History

  • Jun 27, 2022 10:55 pm CDTSources Sought (Original)