Skip to main content

An official website of the United States government

You have 2 new alerts

6515--Temperature Management Machine

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Presolicitation (Original)
  • Original Published Date: Aug 29, 2024 02:27 pm CDT
  • Original Response Date: Sep 06, 2024 04:00 pm CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Sep 21, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 339112 - Surgical and Medical Instrument Manufacturing
  • Place of Performance:
    ,

Description

Statement Of Work MUST be Compatible with Phillips vital sign monitoring equipment currently used at the facility Due to periodic saline shortages we require a resevour Water Temperature Control setting range: 39.2-104.0 F Control accuracy: + or 0.3 C Display measurement accuracy: + or 0.2 C Display/resolution setting: 0.1C Default setting: 104.F (40.0C) Patient Temperature Control setting range: 89.6-100.4F Control accuracy: = or 0.1 C Default setting: 98.6F Circulating Fluid: Sterile distilled water or distilled water Thermal transfer devices such as blankets, vests, and leg wraps Patient temperature probes Reusable adapter cables Reusable hose sets Reusable patient temperature output cable Must be capable of supplying either an individual or multiple thermal transfer devices simultaneously with those circuits being monitored separately. Must have 3 operating modes: Automatic, Manual, and Monitor Closed loop control Controller alarms visual and audible indications for when safety parameters are exceeded or it detects system function or performance irregularities. A display to inform of system status or when the user must confirm a setting selection.

Contact Information

Contracting Office Address

  • VA MEDICAL CENTER 4101 SOUTH 4TH STREET
  • LEAVENWORTH , KS 66048
  • USA

Primary Point of Contact

Secondary Point of Contact





History