Skip to main content

An official website of the United States government

You have 2 new alerts

Z2NZ--502-24-1-5040-0006 Steam Condensate Liner Installation

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Nov 07, 2023 09:51 am CST
  • Original Date Offers Due: Dec 06, 2023 03:00 pm CST
  • Inactive Policy: Manual
  • Original Inactive Date: Jan 05, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: Z2NZ - REPAIR OR ALTERATION OF OTHER UTILITIES
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    ,

Description

Condensate Line Liner Installation Alexandria VAHCS Background: Alexandria VAHCS has a requirement that involves installing a liner into an existing steam condensate pipe. The integrity of the pipe has corroded, providing numerous condensate leaks leading to an increase in make up water needed at the boiler plant. Objective: Award a firm-fixed price contract to a contractor capable of performing installation of liner in existing 2-1/2 condensate line safely, efficiently, and in the manner addressed by the scope of work Scope of Work: Locate middle of expansion loop by means of digging, chip concrete to expose condensate line Remove 2 ½ from expansion loop, provide certified welder to weld flanges on pipe in ground and new 2 ½ SCH 80 steel expansion loop Provide 2 glass liners to shoot, both will be shot from opposite ends of pipe toward middle to meet in center Provide ¼ steel plate to place on concrete tunnel for future access Backfill to existing grade Glass liner to be rated to withstand temperatures up to 350 degrees Provide warranty of no less than 10 years for liner Provide warranty of no less than 2 years on work performed

Contact Information

Contracting Office Address

  • 715 SOUTH PEAR ORCHARD RD., PLAZA 1
  • RIDGELAND , MS 39157
  • USA

Primary Point of Contact

Secondary Point of Contact





History

  • Jan 05, 2024 10:55 pm CSTCombined Synopsis/Solicitation (Original)