VGLZ232028 REPLACE MV FEEDER FROM SW1-11 TO T7C AND REPLACE TRANSFORMER T7C BUILDING 17
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Apr 12, 2023 12:57 pm EDT
- Original Response Date: Jun 05, 2023 10:00 am EDT
- Inactive Policy: 15 days after response date
- Original Inactive Date:
- Initiative:
- None
Classification
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: Z2MZ - REPAIR OR ALTERATION OF EPG FACILITIES - OTHER, INCLUDING TRANSMISSION
- NAICS Code:
- 23713 - Power and Communication Line and Related Structures Construction
- Place of Performance: Selfridge ANGB , MI 48045USA
Description
Selfridge Air National Guard Base, 48045 MI, intends to issue an Invitation for Bids to award a single firm fixed-price contract for services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary for the Construction of VGLZ232028 REPLACE MV FEEDER FROM SW1-11 TO T7C AND REPLACE TRANSFORMER T7C BUILDING 17. The contractor shall coordinate with COR, de-energize the source of electrical supply and follow all safety lock out and tag out procedure for all electrical work including demolition and new work. The Contractor shall replace existing MV Cable from MV SW1-11 to transformer T7C and MV cable with 5/15 kV (15 kV Cu with 133% EPR type insulation) from MV Switch 1-11 to MV transformer T7C in the existing conduits and replace live front MV transformer T7C with new fused dead front loop feed transformer with lightning/surge arrestors and Provide 3rd party testing of conductors and transformer after they are installed.
Attachments/Links
Contact Information
Contracting Office Address
- KO FOR MIANG DO NOT DELETE 43200 MAPLE ST BLDG 105
- SELFRIDGE ANGB , MI 48045-5213
- USA
Primary Point of Contact
- Steven Stocking
- steven.stocking.2@us.af.mil
- Phone Number 5862394881
Secondary Point of Contact
- Anna Randall
- anna.randall.1@us.af.mil
- Phone Number 5862395526
History
- Jun 20, 2023 11:59 pm EDTPresolicitation (Original)
- Jun 06, 2023 04:04 pm EDTSolicitation (Original)