Skip to main content

An official website of the United States government

You have 2 new alerts

Rapid Detection of Mild Traumatic Brain Injury in a Noninvasive Body Fluid Sample

Award Details

  • Contract Award Date: Sep 09, 2022
  • Contract Award Number: W81XWH-22-C-0100
  • Task/Delivery Order Number:
  • Contractor Awarded Unique Entity ID: HRZ1H9YCEBJ8
  • Contractor Awarded Name: MEDICORTEX FINLAND OYJ
  • Contractor Awarded Address: Turku, 20520 FIN
  • Base and All Options Value (Total Contract Value): $2,093,995.00

General Information

  • Contract Opportunity Type: Award Notice (Original)
  • Original Published Date: Sep 12, 2022 07:33 am EDT
  • Inactive Policy: 15 days after contract award date
  • Original Inactive Date: Sep 24, 2022
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: AN12 - HEALTH R&D SERVICES; HEALTH CARE SERVICES; APPLIED RESEARCH
  • NAICS Code:
    • 541715 - Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
  • Place of Performance:
    FIN

Description

Medicortex is developing an easy-to-use, point-of-contact, non-invasive TBI diagnostic tool, which will detect a novel biomarker of TBI, in the form of glycan structures, in non-invasive samples of body fluids, including urine. Medicortex has discovered glycan structures which appear in urine, and has validated their utility as biomarkers for TBI in clinical studies comparing patients with TBI, patients with non-TBI orthopedic injuries, and healthy volunteers. Medicortex will set up a detection method for the glycan biomarker based on the results from prior research and the resolved biomarker structure. The team will optimize the assay platform and chemistry configuration for easy and rapid detection of TBI-related glycans in urine. The performance of glycan detection will be improved through utilizing glycan-specific antibodies generated in the project. At the end of the project, a prototype test will be available in a standard immunoassay/lateral flow cassette. The non-invasive nature of the samples combined with visual detection will facilitate the successful development of a robust diagnostic kit for field use, at the point-of-injury, and for lay use in various situations like military operations, contact sports and mass casualties.

Contact Information

Contracting Office Address

  • BLDG 820 PBO 820 CHANDLER STREET
  • FORT DETRICK , MD 21702-5014
  • USA

Primary Point of Contact

Secondary Point of Contact





History