Perimeter Security Roads Repairs, Cutler, Maine
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Jan 02, 2025 04:54 pm EST
- Original Response Date: Jan 17, 2025 02:00 pm EST
- Inactive Policy: 15 days after response date
- Original Inactive Date: Feb 01, 2025
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code:
- NAICS Code:
- Place of Performance: ME 04626USA
Description
Base Bid Scope:
a. Constructing laydown area to store materials and equipment.
b. Providing payment to regulating authorites for In-Lieu Fee.
c. Raising and widening of exisitng gravel road at work Area G. Constructing stone revetment slope on ocean side of roadway.
The revetment construction will require portions of the Ground Grid to be temporarily cut such that additional length can be added and the grounding wire be lowered in the ground prior to installation of revetment. The grounding wire is to be repaired via exothermic weld. See Specification 01 14 00.00 20 Attachment A for grounding grid work requirements.Installation of several drainage features including a new open bottom box culvert. The open bottom box culvert requires the final design to be provided by the manufacturer.
d. Raising and widening of exisitng gravel road at work Area H. Constructing stone revetment slope on ocean side of roadway.
The revetment construction will require portions of the Ground Grid to be temporarily cut such that additional length can be added
and the grounding wire be lowered in the ground prior to installation of revetment. The grounding wire is to be repaired via exothermic weld. See Specification 01 14 00.00 20 Attachment A for grounding grid work requirements. Installation of several drainage features including a new open bottom box culvert. The open bottom box culvert requires the final design to be provided by the manufacturer.
e. Incidental related work.
Option Work:
Option 1: Roadway safety improvements at Vicker's corner. Improvements include: regrading the roadway, new pavement, guardrail, striping, signage as well as other incidental related work.
Option 2: The removal and replacement of two (2) existing roadway culverts on ridge road. Mill and overlay of approximately 2,800 lf of roadway between B103 and B100. Provide crack seal after mill prior to overlay. Work must be sequenced such that the culverts are replaced prior to the mill and overlay.
Option 3: 2,000 Tons of pavement to be placed along contiguous sections of roadway along the perimeter security roads.
Attachments/Links
Contact Information
Primary Point of Contact
- Matthew Thomsen
- matthew.j.thomsen2.civ@us.navy.mil