Skip to main content

An official website of the United States government

You have 2 new alerts

RADIO FREQUENCY (RF) EMANATIONS TESTING FOR A SHIELDED ROOM

info alert

Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: May 23, 2023 09:14 am EDT
  • Original Response Date: Jun 22, 2023 12:01 am EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jun 22, 2023
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: C219 - ARCHITECT AND ENGINEERING- GENERAL: OTHER
  • NAICS Code:
    • 541330 - Engineering Services
  • Place of Performance:
    Wright Patterson AFB , OH 45433
    USA

Description

The Air Force Life Cycle Management Center, Simulators Division (AFLCMC/WNS), requires Radio Frequency (RF) testing for a 100 square foot room. This testing is required to certify the room to operate without restricting the use of electronic devices within a three-meter perimeter outside of the room.

The contractor shall test and report if the current rFOIL shielding satisfies both below standards for shielding effectiveness:

  1. The Air Force standard for shielding effectiveness (attenuation) for shielded enclosures and global shielding is 50 dB (plus an initial 10-dB allowance for life-time degradation); and
  2. The standard for equipment performing an instrumented test in this environment shall be performed IAW National Security Telecommunications and Information System Security Advisory Memorandum (NSTISSAM/TEMPEST 1-93).

These standards are specified in Air Force Systems Security Instruction (AFSSI) 7702, paragraph 10.4.5.

In addition, the contractor shall:

  • Hold a SECRET clearance or higher;
  • Be capable of sending a visit request via Defense Information for Security System (DISS) web application;
  • Acquire base access to Wright-Patterson Air Force Base, OH;
  • Possess mobile calibrated testing equipment capable of measuring emanations outside of a 100 square foot area shielded room;
  • Transport testing equipment with set-up and break-down.
  • Be certified by the NSA TEMPEST Certification Program (TCP) to perform the Certified Test Service Program;
  • Author a test plan formatted IAW paragraph 2 of the Field Test Memorandum issued by the NSA;
  • After Government approval of the test plan, conduct a test IAW the above outlined requirements; and;
  • Provide final report of test results.