Z2DA--T2 DB 442-22-004 Add Lightning Protection to campus (VA-22-00068380)
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Solicitation (Updated)
- Updated Published Date: Dec 19, 2022 03:39 pm MST
- Original Published Date: Nov 21, 2022 10:55 am MST
- Updated Date Offers Due: Dec 21, 2022 02:00 pm MST
- Original Date Offers Due: Dec 21, 2022 02:00 pm MST
- Inactive Policy: 15 days after date offers due
- Updated Inactive Date: Jan 05, 2023
- Original Inactive Date: Jan 05, 2023
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code: Z2DA - REPAIR OR ALTERATION OF HOSPITALS AND INFIRMARIES
- NAICS Code:
- 236220 - Commercial and Institutional Building Construction
- Place of Performance: Cheyenne , WY 82001USA
Description
In 2019 a Facility Condition Assessment was performed for Cheyenne VA Medical Center. As part of the assessment, it was noted that lightning protection was not in place and a lightning protection risk analysis was recommended. The risk analysis was performed according to the NFPA 780 calculator, resulting from that is the recommendation to install a lightning protection system in the locations identified in this Statement of Work.
The purpose of this Statement of Work (SOW) is to procure services for design, install, system continuity testing, verification and commissioning of a lightning protection system (LPS) for the following buildings as represented on Figure 1 CVAMC Lightning Risk Assessment Drawing dated July 2020; RRTP, 1-CLC, 1-A, 1-B, 1-C, 45, 1-CA, 1-CX, 1-AR, 1-MRI, 11, 12, 13, 31 in addition to the photovoltaic parking canopies at the northeast property location as well as lightning protection for above ground fueling station and oxygen storage tank.
Attachments/Links
Contact Information
Contracting Office Address
- 6162 S WILLOW DR SUITE 300
- Greenwood Village , CO 80111
- USA
Primary Point of Contact
- Joseph Wingfield
- joseph.wingfield@va.gov
- Phone Number 303-712-5769
Secondary Point of Contact
History
- Jan 05, 2023 09:56 pm MSTSolicitation (Updated)
- Nov 21, 2022 09:56 pm MSTPresolicitation (Updated)
- Nov 21, 2022 10:55 am MSTSolicitation (Original)