Z1FZ--Service 463-24-LUMPSUM 944 Boiler Replacement
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Solicitation (Updated)
- Updated Published Date: Jul 18, 2024 04:50 pm PDT
- Original Published Date: Jun 26, 2024 07:26 am PDT
- Updated Date Offers Due: Jul 24, 2024 08:00 am PDT
- Original Date Offers Due: Jul 15, 2024 12:00 pm PDT
- Inactive Policy: Manual
- Updated Inactive Date: Aug 23, 2024
- Original Inactive Date: Aug 14, 2024
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code: Z1FZ - MAINTENANCE OF OTHER RESIDENTIAL BUILDINGS
- NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
- Place of Performance:
Description
36C26024R0097, Amendment 0001 CONTINUATION PAGE It has been determined necessary and in the best interest of the Government to make the following clarifications/revisions to solicitation 36C26020Q0015. Questions and Answers: Q: The existing boiler is glycol. Do you want the replacement boiler to be a glycol or a water boiler, like the one in the adjacent tenement? There were past discussions of matching the two boilers for service and maintenance efficiency. If it is decided to match boilers, can you provide the data for the other boiler. A: Match existing glycol system. This project is independent of other properties. Q: The location of the existing boiler makes it difficult to replace and service. Can the boiler be relocated within the room for ease of installation and maintenance? A: Yes, the boiler can be relocated for ease of access and maintenance. Coordinate with VA FMS prior to final location determination.  Q: Please confirm the intent of the flue replacement is from the existing tee to the boiler. A: Confirmed. A flue submittal is not necessary. Q: Please confirm that the existing glycol make up tank is to be reused. A: Replace existing Glycol tank and provide a submittal for review prior to work. Eliminate condensate neutralizer from scope of work.Â
Attachments/Links
Contact Information
Contracting Office Address
- 1601 E Fourth Plain Blvd Bldg 17 Suite B428
- VANCOUVER , WA 98661
- USA
Primary Point of Contact
- Susan L Howe
- Susan.Howe2@va.gov
Secondary Point of Contact
History
- Aug 23, 2024 09:04 pm PDTSolicitation (Updated)
- Jul 25, 2024 08:55 pm PDTPresolicitation (Original)
- Jul 18, 2024 04:03 pm PDTSolicitation (Updated)
- Jul 17, 2024 03:08 pm PDTSolicitation (Updated)
- Jul 15, 2024 11:40 am PDTSolicitation (Updated)
- Jul 10, 2024 04:29 pm PDTSolicitation (Updated)
- Jun 26, 2024 07:26 am PDTSolicitation (Original)