Skip to main content

An official website of the United States government

You have 2 new alerts

Y1DA--Renovate SPS/SPD (construction) (VA-22-00010727)

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: Jan 12, 2022 03:40 pm EST
  • Original Published Date: Nov 15, 2021 02:14 pm EST
  • Updated Date Offers Due: Jan 20, 2022 10:00 am EST
  • Original Date Offers Due: Jan 06, 2022 10:00 am EST
  • Inactive Policy: Manual
  • Updated Inactive Date: Feb 19, 2022
  • Original Inactive Date: Apr 15, 2022
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: Y1DA - CONSTRUCTION OF HOSPITALS AND INFIRMARIES
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:

Description

The purpose of this amendment is to address additional questions from Industry: 1. On mechanical drawing M-601 schedule note 2, references Enthalpic Core Energy Recovery. The supporting schematic on page M-503 does not include or reference Enthalpic Core Energy Recovery. Please confirm that energy recovery is NOT needed on Air Handling Unit Tagged 1-AHU-SPS. Answer: No, there is no energy recovery on this AHU. 2. The specified LVT comes both as an 18 X 18 and a 6 X 36. Please clarify which size is intended. Answer: 6x36 3. The finish schedule indicates the flooring in two corridors to be patch as needed . Could you please provide more details regarding the extent, and the type of flooring in question? Answer: Existing floor finishes occur at Corridors BB-01, BB-02 and BB-03. The design intent is to leave these floor finishes in place. Contractor to repair and or replace any damage to the floor finish created by construction activities. 4. Is there a mud bed called for at any of the floor tile locations? Answer: See specifications

Contact Information

Contracting Office Address

  • 100 EMANCIPATION DR
  • HAMPTON , VA 23667
  • USA

Primary Point of Contact

Secondary Point of Contact





History