Renovate Officer Unaccompanied Housing F641
Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.
Award Details
- Contract Award Date: Aug 31, 2021
- Contract Award Number: C-21-10-25-226
- Task/Delivery Order Number:
- Contractor Awarded Unique Entity ID: JDAKGNWJL3A1
- Contractor Awarded Name: SOUTHWIND CONSTRUCTION CO, INC
- Contractor Awarded Address: Edmond, OK 73013-3633 USA
- Base and All Options Value (Total Contract Value): $4,490,000.00
General Information
- Contract Opportunity Type: Award Notice (Original)
- Original Published Date: Dec 21, 2021 09:45 am EST
- Inactive Policy: Manual
- Original Inactive Date: Dec 31, 2021
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code: Z1FA - MAINTENANCE OF FAMILY HOUSING FACILITIES
- NAICS Code:
- 236116 - New Multifamily Housing Construction (except For-Sale Builders)
- Place of Performance: Enid , OK 73705USA
Description
PROJECT SUMMARY
Vance Air Force based is considering seeking renovations bids for the renovations to the existing officer dormitories. The main intent of the work is to bring the Officer Dormitory F641 into compliance with Air Force and code requirements, based on the following scope of work:
Replace portions and abandon portions of the existing HVAC system and replace with PTAC system. Repair or replace water damaged drywall near windows. Replacement of windows in each room and the exterior aggregate panels near windows. Renovation of kitchen including: Repair, replace, and renovate surfaces damaged by mold. Installation of anti-scaling system to mitigate hard water build up on kitchen fixtures. Replace electric burners in ranges to make max temperature compliant. Renovation of bathrooms, including but not limited to: Sink with vanities, toilets with full lids, floor tile, shower fixtures, shower surface or liner and drains. Connections for future installation of bidets shall be implemented in eight rooms per facility.
Enclose existing breezeways and repair entrance stairs. Modify site grading, parking, sidewalks, and ramps for compliance with architectural barriers act. Upgrade of electrical service including electrical panel board, transformers, and feeder lines. Renovate two rooms per facility to make accessible. Renovation of fire alarm system within each vestibule, including replacing existing pull station with new at code required locations and providing for new smoke detectors connecting to existing fire alarm panel. Repair and replace worn and damaged surfaces and materials as noted in design drawings.
CONTRACTOR REQUIREMENTS:
The Contractor awarded will need to provide information to have business set up for payment. Also will need to fill out forms for Reps & Certs, W-9, & Authorization Agreement For Vendor Automatic Electronic Funds Transfer. If you are large business you will need to be set up on 45 days net terms and small business will be 30 days Net terms. You must also provide three References of similar like work within the past two years, and Technical Approach in your bid package.
Pre-Bid to look at the site is scheduled on 13 May 21 2 p.m. Central time zone. Please notify teddy.thomas@.ctr@us.af.mil 72 hours in advance by providing your full name, date of birth, state, and driver license for base access. Award will be contingent upon approval of funds, reference checks, D&B rating, and low cost acceptable.
Attachments/Links
Contact Information
Contracting Office Address
- ADMIN ONLY NO REQTN CP 580 213 6770 246 BROWN PKWY STE 228 BLDG 500
- ENID , OK 73705-5037
- USA
Primary Point of Contact
- Teddy T. Thomas
- teddy.thomas.ctr@us.af.mil
- Phone Number 5802137174
Secondary Point of Contact
- Willard Vinson
- willard.vinson.ctr@us.af.mil
- Phone Number 5802135120
- Fax Number 5802136047
History
- May 27, 2022 11:55 pm EDTAward Notice (Updated)
- Jan 31, 2022 11:55 pm ESTAward Notice (Updated)
- Dec 31, 2021 11:55 pm ESTCombined Synopsis/Solicitation (Updated)
- Dec 21, 2021 09:45 am ESTAward Notice (Original)