Breaker Testing Electric Power Distribution System

info alert

Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Nov 08, 2023 10:53 am EST
  • Original Date Offers Due: Nov 22, 2023 12:00 am EST
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Dec 07, 2023
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: J059 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
  • NAICS Code:
    • 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
  • Place of Performance:
    Augusta , GA 30904
    USA

Description

This Statement of Work (SOW) describes the requirements for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all its components at the Charlie Norwood VA Medical Center.  This project will consist of conducting non-destructive testing and repair of all power circuit breakers rated 250 amperes and above, to include testing, calibration, and repair, if necessary, for Uptown and Downtown.  Electrical Breaker shall be serviced/tested in accordance with all manufacturer recommendations. Work shall be accomplished using VHA Directive 1028, Facility Electrical Power Systems Dated 2020.  The testing will be required for the Downtown Division and the Uptown Division of the Charlie Norwood VA Medical Center, Augusta, Georgia.  There are approximately 150 breakers to be tested at the Downtown Division and 150 breakers to be tested at the Uptown Division. Test ground resistance for the entire facility grounding system.  Test ground fault protection devices for proper function if they are installed in the Facility Electrical Power System.  Project shall consist of energized and de-energized testing.