Improve Water System to Reduce Risk of Legionella Contamination and Patient Injury

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Presolicitation (Updated)
  • Updated Published Date: May 08, 2023 09:17 am EDT
  • Original Published Date: May 08, 2023 08:44 am EDT
  • Updated Response Date:
  • Original Response Date:
  • Inactive Policy: Manual
  • Updated Inactive Date: Jun 16, 2023
  • Original Inactive Date: Jun 16, 2023
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: Z2NE - REPAIR OR ALTERATION OF WATER SUPPLY FACILITIES
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Chillicothe , OH 45601
    USA

Description

NOTE 1: This Pre-Solicitation previosly posted to SAM.GOV under 36C25022B0052. 

STATEMENT OF WORK

Improve Water System to Reduce Risk of Legionella Contamination and Patient Injury

The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 10 has a requirement to Improve Water System to Reduce Risk of Legionella Contamination and Patient Injury (Project 538-18-101) at the Chillicothe VA Medical Center, 17273 St. Rt. 104., Chillicothe, OH 45601-9718.

The Contractor shall perform all demolition and construction to provide domestic water system improvements, in accordance with project design documents. The improvements include dead-leg and unused fixture removal; installation of thermostatic mixing valves at point-of-use for scald protection; re-balancing of existing hot water recirculation loops and addition of new recirculation loops; installation of ultraviolet treatment equipment; installation of water monitoring equipment; connection and integration of water monitoring equipment and other water quality related instrumentation to the Building Automation System (BAS); installation of a fiber optic backbone for the BAS; demolition of abandoned equipment in Bldg. 256; relocation of the site domestic water storage tank valving and upgrade to tank instrumentation; and installation of new site water delivery equipment between municipality water meter through Bldg. 256 pump room. The work shall be phased to accommodate the Medical Center’s on-going operations. 

All work shall be closely coordinated with VA Contracting Officer (CO) and Contracting Officer’s Representative (COR).

DURATION OF PROJECT: All work shall be completed within the Period of Performance (POP) indicated in the solicitation. Estimated POP Base bid work to be completed within 868 calendar days after receipt of Notice to Proceed.