Nortek Acoustic Wave and Current (AWAC) Profiler
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Jul 25, 2024 03:29 pm MDT
- Original Response Date: Aug 06, 2024 12:00 pm MDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Aug 21, 2024
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code:
- NAICS Code:
- Place of Performance: USA
Description
Notice Number: 145025240085SM
Notice Type: Sources Sought Synopsis
Title: Nortek Acoustic Wave and Current (AWAC) Profiler
Response Date: August 6, 2024
This is a SOURCES SOUGHT SYNOPSIS and is not a pre-solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified U.S. Domestic businesses, which could include Small Business, HUBZone, 8(a), Service Disabled Veteran Owned, Women Owned Small Business firms and even Large Businesses. Responses to this Sources Sought Synopsis will be used by the Government in making appropriate acquisition decisions.
The National Oceanic and Atmospheric Administration (NOAA), Oceanic and Atmospheric Research (OAR), Great Lakes Environmental Research Laboratory (GLERL) is a multidisciplinary environmental research laboratory that provides scientific understanding to inform the use and management of Great Lakes and coastal marine environments. Acoustic Wave and Current (AWAC) profilers are used as part of the core MIL ReCon mission monitoring the Great Lakes. These AWAC profilers can be used at remote sites that rely on low bandwidth communications, where passing large amounts of data cannot be sent back to the lab. The GLERL requires an AWAC profiler like the Nortek AWAC 600 kHz Profiler.
INTENDED USE/PURPOSE:
The AWAC profiler is used for submerged wave-measurement applications. It is used to capture the full wave spectrum in combination with current profiles. The instrument has a 60 m maximum range for wave measurements, and 2 Hz sampling of the surface elevation and onboard wave processing. It is optimal for medium water-depth current and wave measurements. This is the only known instrument that can meet the Government’s needs, and this notice’s intent is to identify any other products that meet the full requirements listed below.
SPECIAL REQUIREMENTS/ESSENTIAL SALIENT FEATURES:
Water Velocity Measurements:
Maximum profiling range: 50 m
Cell size: 0.5-8.0 m
Number of cells: 200
Velocity range: ±10 m/s horizontal, ±20 m/s upon request
Accuracy: ±1% of measured value ±0.5 cm/s
Velocity precision: Consult instrument software
Maximum output rate: 1 Hz or 2 Hz
Internal sampling rate: 8 Hz
Echo Intensity (along slanted beams):
Sampling: Same as velocity
Resolution: 0.45 dB
Dynamic range: 90 dB
Transducer acoustic frequency: 600 kHz
Number of beams: 3 beams 120° apart, one vertical beam, (90° apart, one at 5° for platform mount)
Beam width: 1.21° (2.42° total)
Beam width vertical beam: 1.93° total
Wave Measurement Option (AST):
Maximum depth: 60 m
Data types: Pressure, one velocity along each beam, AST
Sampling rate velocity: (output) 2 Hz
No. of samples per burst: 512, 1024 or 2048 (Contact Nortek for other burst configurations)
Wave Estimates:
Range: -15 to 15 m
Accuracy/resolution (Hs): < 1% of measured value / 1 cm
Accuracy/resolution (Dir): 2° / 0.2°
Period range: 1-50 s
Cut-off period (Hs): 5 m depth: 0.5 sec, 20 m depth: 0.9 sec, 60 m depth: 1.5 sec
Cut-off period (dir): 5 m depth: 1.5 sec, 20 m depth: 3.1 sec, 60 m depth: 5.5 sec
Sensors:
Temperature: Thermistor in head (sampled at meas. rate)
Temp. range: -4 to +40 °C
Temp. accuracy/resolution: 0.1 °C/0.01 °C
Temp. time response: 2 min
Compass: Solid State magnetometer (max 1 Hz sample rate)
Accuracy/resolution: 2° for tilt < 30°/0.01°
Tilt: Solid State accelerometer (max 1 Hz sample rate)
Accuracy/resolution: 0.2° for tilt < 30°/0.01°
Maximum tilt: Full 3D
Up or Down: Automatic detect
Pressure: Piezoresistive (sampled at meas. rate)
Range: 0-100 m (inquire for options)
Accuracy/Precision: 0.1% FS / Better than 0.002% of full scale
Data Recording:
Capacity: 16 GB, 64 GB or 128 GB (inquire for larger capacity)
Data record: Consult instrument software
Mode: Stop when full
Real-Time Clock:
Accuracy: ±1 min/year
Clock retention in absence of external power: 1 year. Rechargeable backup battery
Data Communications:
Ethernet: 10/100 Mbits Auto MDI-X, TCP/IP, UDP/IP, HTTP protocols, Fixed IP / DHCP client /Auto IP address assignment, UPnP and Nortek proprietary instrument, discovery over Ethernet
Serial: Configurable RS-232/RS-422 300-1250000 bps
Recorder download baud rate: 20 Mbit/s (Ethernet only) - 1 GB in 6 minutes
Controller interface: ASCII command interface over Telnet and serial
Connectors:
Standard: MCBH6F (Ethernet) + MCBH8F (serial and/or battery)
Optional: MCBH6F (Ethernet) + Souriau M-series metal connector for online use (10M) + MCBH2F (battery)
Software:
Functions: Deployment planning, instrument configuration, data retrieval and conversion (for Windows®)
Power:
DC input: 12-48 V DC
Maximum peak current: 1.5 A
Max. average consumption at 1 Hz: 8 W at 1 Hz, Ethernet adds 0.75 W
Typical average consumption: 15 mW
Sleep consumption: 100 μA, power depending on supply voltage
Transmit power per beam: 0.3-30 W, adjustable levels
Ping sequence: Parallel
Environmental:
Operating temperature: -4 to +40 °C
Storage temperature: -20 to +60 °C
Vibration: IEC60068-2-64
EMC approval: IEC/EN 61000-6-2, 61000-6-3
Depth rating: 300 m
Materials:
Standard model: POM with titanium fasteners
Dimensions:
Maximum diameter: 215 mm
Maximum length: 203 mm
Weight:
Weight in air: TBC
Weight in water: TBC
Online Cable:
Polyurethane jacket, Shore D hardness, 13mm in diameter, max 500m. Inquire for longer cables
Batteries:
External: 540Wh (alkaline) or 1800 W (lithium)
DELIVERY SCHEDULE:
Deliver by December 1, 2024.
The North American Industry Classification Code (NAICS) is 334511 with a size standard of 1,350 employees.
Interested firms shall provide, in writing, a brief narrative (no more than 3 pages in length) and documentation to support your firm’s capability and experience meeting the requirements herein and include your firm’s name, address, point of contact, telephone number, UEID Number, CCR CAGE Number, business type and size (i.e., small, large, non-profit, educational, etc.). Any response that does not include this information will not be considered. The Government will review your response to determine if your firm has the experience, knowledge and capability to provide the items as specified above.
This request for information does not constitute a commitment, implied or otherwise, that a procurement action will be issued. Nor does this request for information constitute a commitment, implied or otherwise, that any procurement action may be issued for the Government’s requirements.
No entitlement to payment of direct or indirect costs or charges by the Government will arise because of the submission of contractor’s information. The Government shall not be liable for or suffer any consequential damages for proprietary information not properly identified. Proprietary information will be safeguarded in accordance with the applicable Government regulations.
All contractors doing business with the Government are required to be registered and active with the System for Award Management (SAM) website.
NOTE: THIS SYNOPSIS IS NOT CONSIDERED A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION ONLY. No solicitation document is available. No contract will be awarded based on responses received to this notice.
Attachments/Links
Contact Information
Primary Point of Contact
- MAS, STEPHANIE
- STEPHANIE.MAS@NOAA.GOV
- Phone Number 3035786768