Skip to main content

An official website of the United States government

You have 2 new alerts

JBSA Lackland Air Handler Unit

Award Details

  • Contract Award Date: Mar 04, 2022
  • Contract Award Number: FA301622P0054
  • Task/Delivery Order Number:
  • Contractor Awarded Unique Entity ID: LF28JANGC8D3
  • Contractor Awarded Name: Micah Property Management Inc
  • Contractor Awarded Address: Duncanville, TX 75116-4923 USA
  • Base and All Options Value (Total Contract Value): $48,000.00

General Information

  • Contract Opportunity Type: Award Notice (Original)
  • Original Published Date: Mar 04, 2022 04:31 pm EST
  • Inactive Policy: 15 days after contract award date
  • Original Inactive Date: Mar 19, 2022
  • Initiative:
    • None

Classification

  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    JBSA Lackland , TX 78236
    USA

Description

The Contractor shall be responsible for all required materials, equipment andpersonnel to manage, administer, and supervise the project. All workmanshipshall be of good quality and performed in a skillful manner as determined by theProject Manager (PM). Contractor shall remove existing motor and blowerassembly. Install 2 Geenheck Model Plenum fans (Vari-green EC motor, dial forbalancing) or equal to. Contractor shall modify the electrical to accommodatethe new motors for the AHU. Contractor shall retrofit new bower assembly,create a wall in the AHU, and blank off any gaps to create a discharge plenum tobe installed. Contractor shall repair any items required for testing the operationof Air Handlers mechanically, and make necessary electrical modifications fornew motors at Building 2000 rear mechanical room. Contractor shall supply thematerials and service described in this document below. All work shall beconducted in compliance with the American Society of Heating and Air-Conditioning Engineers (ASHRAE) standards. This is a turnkey install and startup. Contract shall result in a fully operational system. 502 CE shall not provideany materials, tools or equipment.

Contact Information

Contracting Office Address

  • ADMIN ONLY NO REQTN CP 210-671-3617 1655 SELFRIDGE AVE BLDG 5450
  • JBSA LACKLAND , TX 78236-5286
  • USA

Primary Point of Contact

Secondary Point of Contact

History