Z1DA--Correct Fire and Smoke Damper Deficiencies - 583-24-511

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: May 29, 2024 03:16 pm EDT
  • Original Published Date: Apr 26, 2024 09:14 am EDT
  • Updated Date Offers Due: May 31, 2024 02:00 pm EDT
  • Original Date Offers Due: May 31, 2024 02:00 pm EDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Jun 30, 2024
  • Original Inactive Date: Aug 29, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: Z1DA - MAINTENANCE OF HOSPITALS AND INFIRMARIES
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:

Description

Questions and Answers: Add #1 stated as builts will be provided before bid date? The dampers shown on the as-builts attached to this addendum include all but four dampers included in the scope of this project, as well as many more. Please reference the list of corrections attached to the solicitation when viewing these drawings. The four dampers not in the drawings have had their locations verified and are included in the list attached to the solicitation Is there a list with damper sizes There is no complete list with damper sizes due to incomplete records. The average size of known fire dampers is 24"Wx16"H SD replacement calls out for a mixing damper to be installed is there a spec on this damper also is this SD to be removed and the mixing damper installed in the duct work? The smoke dampers are 46"Wx62"H and the actuators are 24V. The smoke dampers are all in a plenum accessed from a mechanical room. There will be no duct work or access panels for the smoke dampers. Under Unknown will any work associated with this be as a change order to the contract? The dampers that need to be verified may require contract modifications if a full replacement is necessary. In General without actually visiting each individual damper to review accessibility, size and or obstructions to put together a accurate proposal Each individual damper will need to be verified as part of this project.

Contact Information