Replace Two 12, 470V to 480V Transformers

info alert

Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: Jul 15, 2024 10:56 am MDT
  • Original Published Date: Jun 12, 2024 03:51 pm MDT
  • Updated Date Offers Due: Aug 23, 2024 03:00 pm MDT
  • Original Date Offers Due: Aug 05, 2024 01:00 pm MDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Jun 12, 2025
  • Original Inactive Date: Jun 12, 2025
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Updated Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Z2EB - REPAIR OR ALTERATION OF MAINTENANCE BUILDINGS
  • NAICS Code:
    • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • Place of Performance:

Description

This Statement of Work (SoW) defines requirements for the completion of project to replace two 12,470v to 480v transformers and install a 200A panelboard located in Building 27497 on Kirtland Air Force Base (KAFB). Replace the two current transformers like for like and associated equipment and wiring as necessary to reconnect to and from existing equipment and power.The two transformers are in building 27497. The first transformer is for stepping up power from 500KW generator feeders from 480 VAC to 12470 VAC to power buildings 27496, 27494, and 27497. The second transformer is for stepping down 12470 VAC to 480 VAC to power buildings 27497, 27492, 29081, 29082, and 29083. The transformers are outdated and are from original construction of building. The two transformers are in building 27497. The first transformer is for stepping up power from 500KW generator feeders from 480 VAC to 12470 VAC to power buildings 27496, 27494, and 27497. The second transformer is for stepping down 12470 VAC to 480 VAC to power buildings 27497, 27492, 29081, 29082, and 29083. The transformers are outdated and are from original construction of building.