Skip to main content

An official website of the United States government

You have 2 new alerts

Marakek Solvent Distiller

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Oct 30, 2023 09:53 am HST
  • Original Published Date: Oct 26, 2023 10:38 am HST
  • Updated Date Offers Due: Nov 06, 2023 12:00 am HST
  • Original Date Offers Due: Nov 06, 2023 12:00 am HST
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: Nov 21, 2023
  • Original Inactive Date: Nov 21, 2023
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: 4235 - HAZARDOUS MATERIAL SPILL CONTAINMENT AND CLEAN-UP EQUIPMENT AND MATERIAL
  • NAICS Code:
    • 562211 - Hazardous Waste Treatment and Disposal
  • Place of Performance:
    Honolulu , HI 96819
    USA

Description

update 10/30/23: descaling required items. only items required is:

Specifications:

  • total volume: 12 Gallons
  • 2.5 KW, explosion proof heater; Temp range: 122 F-392F/ 50C-200C
  • Manual Sludge discharge
  • Control panel is CSA/UL approved
  • 208-240v AC, single phase, 50/60 Hertz 12 Amps
  • 90 PSI clean consistent air
  • Dimensions
  1. System- 26x26x62
  2. Vacuum tank- 20x18x40

Lining bags- package of 100

----------------------------------------------------------------------------------------------------------------------------------------------------------

The United States Coast Guard, Base Honolulu requires a Marakek Solvent Distiller, no substitutions.

Specifications:

  • total volume: 12 Gallons
  • 2.5 KW, explosion proof heater; Temp range: 122 F-392F/ 50C-200C
  • Manual Sludge discharge
  • Control panel is CSA/UL approved
  • 208-240v AC, single phase, 50/60 Hertz 12 Amps
  • 90 PSI clean consistent air
  • Dimensions
  1. System- 26x26x62
  2. Vacuum tank- 20x18x40
  • Vacuum assistance
  • Automatic filling
  • Stainless steal condenser
  • Nitrocellulose safety features
  • High heat upgrade
  • Lining bags- package of 100

Submit quotes to justin.n.hinkle@uscg.mil, please review combined Synopsis/solicitation file for further details 