Repair Kit, Rod and Seal

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: Dec 06, 2022 08:16 am EST
  • Original Published Date: Dec 06, 2022 08:15 am EST
  • Updated Date Offers Due: Dec 21, 2022 12:00 pm EST
  • Original Date Offers Due: Dec 16, 2022 12:00 pm EST
  • Inactive Policy: Manual
  • Updated Inactive Date: Dec 22, 2022
  • Original Inactive Date: Dec 31, 2022
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: 2040 - MARINE HARDWARE AND HULL ITEMS
  • NAICS Code:
    • 332510 - Hardware Manufacturing
  • Place of Performance:

Description

Line No 1.

NSN: 2040-01-496-9422

Part No: FL-2605-29 PC37

DESC: REPAIR KIT, ROD AND SEAL

QTY 18 EA

Line No. 2

NSN: 3040-01-496-9424

Part No: 4.00CC-2HLTS24AC16.00

Desc: CYLINDER ASSY, ACTUATING, LINEAR

QTY 10 EA

Line No. 3

NSN: 5315-01-515-9868

Part No: FL-2605-13 SHT 5

Desc: PIN,STRAIGHT, HEADLESS

QTY: 04 EA

Line 1:

REPAIR KIT, ROD AND SEAL, MANUFACTURED IN ACCORDANCE WITH SFLC SPECIFICATION P-573-0502 WITH THE FOLLOWING MODIFICATION:

THE CONTRACTOR SHALL NOT DRILL THE 3/4 INCH HOLE THROUGH THE EXTENSION ROD AS INDICATED ON DETAIL 51-C OF USCG DRAWING FL-2605-29 REV. L SHEET 7 (ELEVATION ZONE 51D).

THIS HOLE WILL BE DRILLED IN THE FIELD AT TIME OF INSTALLATION.

SEE SFLC SPEC P-573-0502, CHANGE 3 FOR PACKAGING, MARKING AND BAR CODING REQUIREMENTS.

PRESERVATION, PACKING, & MARKING SHALL BE IN ACCORDANCE WITH SPECIFICATIONS:

SFLC SPECIFICATION P-573-0502 CHANGE 3 DATED: 10/30/17

EACH KIT PACKED IN ITS OWN BOX AND MARKED.

Line 2:

CYLINDER ASSY, ACTUATING, LINEAR BUILD TO SERIAL # FF346811 B PARKER SERIES 2H, HYDRAULICALLY OPERATED, SIDE LUG MOUNTING STYLE, 4 INCH BORE DIAMETER, 2.5 INCH ROD DIAMETER, 16 INCH STROKE LENGTH, SINGLE ROD END, SYSTEM OPERATING PRESSURE: MAX300 PSI, MIN 200 PSI.

END SUPPORT CASE IS FIXED AND RIGIDLY GUIDED, PISTON SEAL TYPE:

LIPSEAL CLASS1 NITRILE, POLYURETHANE (STANDARD).

INLET AND OUTLET PORTS#12 SEA STRAIGHT THREAD O-RING, PISTON ROD STUD TO HAVE 1 7/8-12 TYPE A UNF STANDARD THREADS, HEAD END AND CAP END TO HAVE PORT IN POSITION 1, CUSHION IN POSITION 2, AND AIR BLEEDS IN POSITION 4. ROD GLAND ASSEMBLY SEAL CONSISTING OF 1 EACH LIPSEAL AND

1 EACH WIPER SEAL. CYLINDER HOUSING-STEEL TUBING: PISTON ROD-CHROME PLATED CARBON STEEL.

INDIVIDUALLY PACKAGED IN ACCORDANCE WITH MIL-STD-2073-1 E METHOD 10, CUSHIONED IN A DOUBLE LAYER OF 3/4 IN BUBBLE WRAP AND PACKED IN AN APPROPRIATELY SIZED ASTM-D6880 CLASS 2 HEAVY DUTY SCREWED WOODEN BOX.

MARKING IAW MIL-STD-129R.

PRESERVATION, PACKING, & MARKING SHALL BE IN ACCORDANCE WITH SPECIFICATIONS:

SEE DESCRIPTION SPEC DATA DATED: 11/08/22

SEE DESCRIPTION SPEC DATA

Line 3:

LEVEL WIND PIVOT PIN.

MANUFACTURE IAW DRAWING FL-2605-13 REVISION C, SHEETS 1, 5 AND 6.

RUNOUT TOLERANCE SHALL BE HELD TO +/-.001" ON THE 8", 8 1/4" DIAMETERS AND FLANGE FACE.

QA INSPECTION SHALL CONSIST OF: 100% DIMENSIONAL, SURFACE FINISH AND RUNOUT READINGS.

THERE WILL BE NO ACCEPTANCE OUTSIDE OF THE DIMENSIOANL CONFORMANCE AS WE HAVE TRIED THIS IN THE PAST AND HAS CREATED PROBLEMS.

END ITEM IDENTIFICATION : BUOY CHAIN WINCH ASSEMBLY, P/N CW1 ABOARD 225 FT WLB, 175 FT WLM, AND 240 FT WLBB GLIB PROJECT COAST GUARD VESSELS NO WAIVERS WILL BE GRANTED FOR THESE ITEMS!!!!

PRESERVATION, PACKING, & MARKING SHALL BE IN ACCORDANCE WITH SPECIFICATIONS:

SEE DESCRIPTION DATED: 11/08/22

PACKAGE AND MARK INDIVIDUALLY.

 - NO SUBSTITUTIONS.