Skip to main content

An official website of the United States government

You have 2 new alerts

4120--Supply: ABB HVAC VFD's

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: Feb 12, 2024 03:52 pm EST
  • Original Published Date: Feb 02, 2024 09:39 am EST
  • Updated Date Offers Due: Feb 21, 2024 01:00 pm EST
  • Original Date Offers Due: Feb 19, 2024 01:00 pm EST
  • Inactive Policy: Manual
  • Updated Inactive Date: Mar 22, 2024
  • Original Inactive Date: Mar 20, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: 4120 - AIR CONDITIONING EQUIPMENT
  • NAICS Code:
    • 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
  • Place of Performance:

Description

The purpose of this amendment is to post the responses to the questions posed. ***Q&A window will close 02/14/2024. *** Q&A We will need to know if these are pumps/fans/variable torque loads or constant torque loads. The VFD s will serve as the power source between the main service panel and fan motors of each air handler, the load varies during a power outage or voltage drop, the fans will constantly run at a set parameter within the VFD. We also need to know the required short circuit rating desired e.g 65KAIC, etc. and if an input circuit breaker or disconnect is needed as well. The required short circuit rating desired current rating must be followed by the manufacture s recommendations and specifications chart that s provided with each VFD purchase, current, size, and voltage, we will utilize the I/O terminals for the motor control. Do you need a circuit breaker or fusible disconnect switch? ABB ACH550 VFD s has a disconnect switch/Circuit breaker mounted on the VFD, non-Fusible. What is the required SCCR for the panel? The required SCCR for the panel 100KA. Do you want the VFD keypad mounted on the enclosure door? The VFD will be mounted on the opposite side of the wall or the air handler, designated mounting brackets. What pilot devices are required (H-O-A switch, VFD-Off-Bypass switch, Run light, Fault light, etc.). AAB VFD has and, H-O-A switch and VFD bypass switch with run/fault indicators. Is the application for variable torque or constant torque? Constant torque, the VFD at times will ramp down however the horse power remains the same. The specification mentions 0.5Hz to 200Hz as the frequency range.  Is this just a typical manufacturer spec or do you really need frequency above 60Hz?  If the answer is above 60Hz, then the application details are critical.  As you know available torque rolls off linearly above 60Hz, so by the time they hit 200Hz, the motor would theoretically only be able to produce about 60 / 200 = 30% of its rated torque.  The real number will be lower because higher speeds increase the friction and windage losses.  My best guess is that 20% is more realistic. This is the manufactures specifications, we operate under 60 hertz we average our motors at 35 to 45 hertz, the manufacture specifies what the VFD capabilities can achieve if needed. I have a question regarding the VFD s on this request. I am assuming you are replacing existing Installed VFD s, would you happen to know or have the unit information that these VFD s are installed on? ABB is a manufacturer of VFD drives, but the drives are installed in bigger Air Conditioning assemblies. If the existing unit information is provided, I may be able to locate the exact VFD that works for said unit. The VFD s are installed on Air Handler #12-2C Service Bay 2-5, building 100.

Contact Information

Contracting Office Address

  • 8875 HIDDEN RIVER PARKWAY
  • TAMPA , FL 33637
  • USA

Primary Point of Contact

Secondary Point of Contact





History