Skip to main content

An official website of the United States government

You have 2 new alerts

HAFB Pressure Vessels

info alert

Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: May 02, 2022 08:56 am EDT
  • Original Published Date: Apr 01, 2022 08:11 am EDT
  • Updated Date Offers Due: May 09, 2022 12:00 pm EDT
  • Original Date Offers Due: May 02, 2022 12:00 pm EDT
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: May 24, 2022
  • Original Inactive Date: May 17, 2022
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: J043 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PUMPS AND COMPRESSORS
  • NAICS Code:
    • 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
  • Place of Performance:
    Hanscom AFB , MA 01731
    USA

Description

PROPOSAL DUE DATE EXTENDED TO 9 MAY 12:00PM 

The contractor shall inspect and test all heat exchangers, compressors, safeties and flash tanks per the requirements of AFI 32-1068. The contractor is responsible for all coordination required to perform inspection/testing. It shall be assumed that no inspections have been performed. The contractor is responsible for restoring equipment to its original condition including insulation. For flash tanks, heat exchangers and compressors the contractor shall perform a type VC inspection every year with UTM (Ultra Sonic thickness measurement) of the pressure shell. The contractor shall promptly notify CE when a pressure vessel is unsafe to operate. The contractor shall put a copy of the inspection report in a protective casing supported to the pressure vessel and appropriate for the environment. Casing must be approved by the government representative before mounting. Submit a Final Pres- sure Vessels Inspections Report, with all unit inspection reports assembled in one document, within 14 days following the final field inspection. The Contractor will be responsible for coordinating required outages.

Please see the attached Performance Work Statement (PWS) for full description of services. 