179 COG Uninterruptable Power Supply

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Jul 31, 2024 07:33 am EDT
  • Original Response Date: Aug 06, 2024 10:00 am EDT
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: Aug 21, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: 6150 - MISCELLANEOUS ELECTRIC POWER AND DISTRIBUTION EQUIPMENT
  • NAICS Code:
    • 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing
  • Place of Performance:
    44903
    USA

Description

NOTICE: Sources Sought     

SOLICITATION NUMBER: W50S8R24R5029

RESPONSE DATE: 6 August 2024 10:00 AM EST

NAICS Code: 335999

This announcement constitutes a Sources Sought Synopsis (market survey). This is not a request for quote (RFQ) or a request for proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The Government will not pay for any cost incurred in responding to this announcement. Any information submitted by respondents to this Sources Sought synopsis shall be voluntary.

This Sources Sought Notice is for Market Research purposes only. The information submitted in response to the Sources Sought Notice will not be utilized to determine vendor standing in any future/potential Request for Quote/Request for Proposal, nor will it be utilized to determine if a vendor is qualified to submit a Request for Quote/Request for Proposal for any future/potential requirement. The notice and the information received shall not be used to determine how well respondents can perform a requirement, which can only be evaluated in response to a solicitation. Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought request. All future/proposed submissions/solicitations requirements solicited on a Government Point of Entry will be evaluated independent of any information submitted in response to this Sources Sought Notice. No vendor will be provided information on solicitations issued on a Government Point of Entry based on this Sources Sought request.

This Sources Sought Notice is relative to the NAICS code 335999. Large and Small Businesses are invited to answer this market survey to determine market capabilities.

The 179th CW/MSC, Mansfield, OH, is conducting market research to determine the existence of potential sources to provide uninterrupted power supply meeting the following salient characteristics:

CLIN

Salient Characteristics

0001 - UPS

Input voltage: 120V

Output voltage: 120V

Kw rating: 1000

Rated power in VA: 1440 VA

Input connection type: NEMA 5-15P

Output connection type (min qty):  NEMA 5-15R (6)

Number of rack units: 2U

Battery Type: Lead Acid

Color: black or grey/silver (no white)

Mounting mode: Rack-mounted

Battery runtime: minimum of 15 minutes at 50% load capacity (500 W)

Other: ability to connect to and be managed via a network connection.

0002 - UPS

Input voltage: Range of 150-280VAC

Output voltage: 120/208 (configurable)

Kw rating: 6000W

Rated power in VA: 6000 VA

Input connection type: hard wired

Output connection type (min qty): hard wired 

Number of rack units: Double conversion

Battery Type: Lead Acid

Color: black or grey/silver (no white)

Mounting mode: Rack-mounted

Battery runtime: minimum 3 minutes backup time on based on 50% load

Other: ability to connect to and be managed via a network connection.

NOTE: Please submit electronic response indicating capability to provide services (no more than 3 pages) as well as POC (name, telephone # and email address) along with contractor’s CAGE, DUNS, and the physical location of your facility to the individuals listed within this notice.

Required Information: Any interested party who can offer all of the above may submit a written reply of not more than 3 pages, addressing each of the above items and defining how their location is capable of ALL of the minimum requirements listed above.

Response Deadline: 10:00 AM EST, 6 August 2024