WNY-111 DBB VOE ADMIN RESET RENOVATION, WASHINGTON NAVY YARD, WASHINGTON DC

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Jul 17, 2024 09:07 am EDT
  • Original Published Date: Jun 13, 2024 11:57 am EDT
  • Updated Date Offers Due: Jul 17, 2024 02:00 pm EDT
  • Original Date Offers Due: Jul 17, 2024 02:00 pm EDT
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: Aug 01, 2024
  • Original Inactive Date: Aug 01, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: Y1AA - CONSTRUCTION OF OFFICE BUILDINGS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Washington , DC
    USA

Description

*** This Solicitation is reserved exclusively for the vendors of the $750M 8(a) MACC (Multiple Award Contract) Managed out of NAVFAC Washington***

The work includes renovation of existing WNY-Building 111 for CNIC Headquarters based on Distributed Workforce initiative with minor SRMimprovements, maximize use of existing offices & cubes, and added collaboration spaces. Construction improvements will include new permanent walls, new system furniture, and reuse/relocation of existing systems furniture and incidental related work. The work also includes mitigating water leakage at select portions of Building 111, including:

  1. Leak 1 at Suite 301, along Column Line 7, along the cement plaster clad rising wall at the east end of the north vertical addition.
  2. Leak 2 at brick masonry above the heads of the multistory curtain wall at the south elevation.
  3. Leak 3 at Suite 401 and Level 3 atrium at the curbed skylights at the roof.
  4. Leak 4 at Suite 501 ceiling under the southeast portion of the sloped roof at Level 5.
  5. Leak 5 at Suite 304, along the building transition between the north and south portions of the buildings at the brick masonry pilasters.