Notice of Intent to Use Brand Name Specifications for Rubber Membrane Coating and Topcoat
Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Sources Sought (Updated)
- Updated Published Date: Nov 09, 2022 03:50 pm CST
- Original Published Date: Aug 30, 2022 03:02 pm CDT
- Updated Response Date: Sep 14, 2022 04:00 pm CDT
- Original Response Date: Sep 14, 2022 02:00 am CDT
- Inactive Policy: Manual
- Updated Inactive Date: Sep 14, 2022
- Original Inactive Date: Sep 14, 2022
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code:
- NAICS Code:
- 238160 - Roofing Contractors
- Place of Performance: New Orleans , LA 70129USA
Description
The U.S. Army Corps of Engineers, Mobile District (SAM) intends to place a brand name specification into solicitation W9127823R0003 in accordance with FAR 6.302. Interested persons may identify their capability to respond to the requirement. This notice is not a request for competitive proposals; however, all information received by the date indicated in this notice will be considered by the Government. A determination by the Government not to include this proposed brand name specification based upon responses to this notice is solely within the discretion of the Government. The U.S. Army Corps of Engineers, Directorate of Contracting, is conducting a market survey to identify alternate sources for Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat to be applied on a modified bitumen roofing system.
The U.S. Army Corps of Engineers, Mobile District, anticipates a future procurement for the FY-23 Michoud Assembly Facility (MAF) Building 103 Roof Replacement project located at Stennis Space Center (SSC), AL. The existing Building 103 modified bitumen roofing system was designed and installed in 2001. The existing system is a GAF Styrene-Butadiene-Styrene modified bitumen roof on tapered insulation and is nearing the end of its useable lifespan. Repairs on the roofing system for minor leaks, tornado damage, and punctures have been completed.
During various assessments it has been noted the roof must endure standing water for extended periods of time. The required solution must be 100% waterproof and not degrade in standing water. Any equal product must be an instant setting spray applied membrane that is rated to be waterproof and resist ultraviolet degradation while having been tested to adhere with the modified bitumen roofing system. An equal product should also meet the following physical characteristics:
- 1,200% elongation
- Greater than 600 psi tensile strength (aged result)
- Class A Fire Rating
- Impermeable – withstands ponding water indefinitely
- Zero VOCs, Water-based and odor free
- Instantly rain resistant
- Chemical resistant to acids and salts
- Provides “severe hail resistance” (ASTM 4470)
- Able up to reach 990 psf uplift resistance (actual uplift is dependent on substrate that product is applied to)
- Water permeance 0.1 perms
This request is not a request to be placed on a solicitation mailing list. It is for information only and is not a request for proposal (RFP) or announcement of a solicitation. The purpose of this notice is to understand the market for alternative suppliers of roof membrane replacement systems meeting the requirements above. It is the Government’s intent to specify the Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat Brand Name for use in the project solicitation described above. Firms shall provide:
- Manufacturer's name and Unique Entity Identifier (UEI) if applicable
- Product data and written statement of compliance with stated requirements. Examples may be Factory Mutual (FM) uplift testing for application of your product to a modified bitumen roofing system hybrid roof system verifying the adherence properties. In addition, the patch and repair process for making modifications or repairs to roof system.
- Previous joint letters of warranty for similar applications providing a 25-year (or greater) manufacturer’s No Dollar Limit (NDL) warranty.
- The written statement of compliance shall include necessary backup design information and supporting documentation. A list of projects in which the spray on membrane has met similar requirements for similar applications shall be provided. The list shall include the exact location of project(s) and a point of contact with phone numbers. The Government will not pay for any material provided in response to this notice nor return the data provided.
Responses should be sent to eric.j.hurtado@usace.army.mil and jennifer.h.suit@usace.army.mil no later than stated response time. No other forms of transmission are requested or will be accepted.
Attachments/Links
Contact Information
Contracting Office Address
- KO CONTRACTING DIVISION 201 SAINT MICHAEL STREET
- MOBILE , AL 36602-3630
- USA
Primary Point of Contact
- Eric Hurtado
- eric.j.hurtado@usace.army.mil
- Phone Number 2156902571
Secondary Point of Contact
- Jennifer Suit
- jennifer.h.suit@usace.army.mil
History
- Nov 26, 2022 10:56 pm CSTSources Sought (Updated)
- Nov 09, 2022 03:50 pm CSTSources Sought (Updated)
- Sep 14, 2022 10:56 pm CDTSources Sought (Updated)
- Aug 30, 2022 03:02 pm CDTSources Sought (Original)