Laser Surgical Handpiece, Erbium YAG laser 2940 nm wavelength
Note: There have been new actions to this contract opportunity. To view the most recent action, please click here.
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
General Information
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Nov 08, 2022 07:40 am EST
- Original Response Date: Nov 11, 2022 11:59 pm EST
- Inactive Policy: 15 days after response date
- Original Inactive Date:
- Initiative:
- None
Classification
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
- NAICS Code:
- 339113 - Surgical Appliance and Supplies Manufacturing
- Place of Performance: Fort Bliss , TX 79918USA
Description
Handpiece must be compatible with Joule Laser System ECN# 086210, Sciton. Handpiece must generate Erbium:YAG laser 2940 nm wavelength. Handpiece software must be compatible with Sciton Joule Laser System computer. Handpiece must be able to generate a laser for ablation to the depths ranging from 25 micrometers to1000 micrometers Handpeice must be able to generate laser in a profractioaned pattern ranging from 1.3 mm x 1.3 mm to 20 mm x 20 mm in size. Handpiece must be able to adjust treatment area percentage from 5.5% to 22% with the generated laser. Handpiece must be capable to genererate laser for coagulation depth of 50 micrometers to 150 micrometers. Vendor must provide Handpiece software install. Vendor will provide initial set up of handpiece to laser system. No grayed/refurbished. New Equipment Only. Operator/User Manual 2 each. Module - (High speed 430micron with randomized pattern software) - requires 2940 module. The scanner handpiece needs to be compatable with the M8527M Joule Laser system. The handpiece allows the use of the ER:YAG 2940 nm laser to penetrate deep into the dermis to treat disfiguring scars. The laser system with handpiece treats disfiguring scars.
Attachments/Links
Contact Information
Contracting Office Address
- MEDICAL READINESS CONTR OFFICE WEST 3160 MCINDOE BLDG1103
- JBSA FT SAM HOUSTON , TX 78234-4504
- USA
Primary Point of Contact
- Elizabeth Orloski
- elizabeth.a.orloski.civ@health.mil
- Phone Number 763-300-4298
Secondary Point of Contact
- Emerita Torres
- emerita.torres.civ@health.mil
History
- Nov 27, 2022 11:56 pm ESTSources Sought (Updated)
- Nov 08, 2022 07:54 am ESTSources Sought (Updated)
- Nov 08, 2022 07:41 am ESTSources Sought (Updated)
- Nov 08, 2022 07:40 am ESTSources Sought (Original)