Skip to main content

An official website of the United States government

You have 2 new alerts

4610-- WATER PURFICATION SYSTEM HCC1 LAB

Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information

  • Contract Opportunity Type: Presolicitation (Original)
  • Original Published Date: Feb 29, 2024 09:50 am EST
  • Original Response Date: Mar 06, 2024 10:00 am EST
  • Inactive Policy: Manual
  • Original Inactive Date: Mar 11, 2024
  • Initiative:
    • None

Classification

  • Original Set Aside:
  • Product Service Code: 4610 - WATER PURIFICATION EQUIPMENT
  • NAICS Code:
    • 333310 - Commercial and Service Industry Machinery Manufacturing
  • Place of Performance:
    ,

Description

VA Chesapeake Community Based Outpatient Clinic (CBOC) Chesapeake HCC1 Salient Characteristics Water Purification System that is capable of producing not less than 200 liters of water per hour, fitted with deionization capabilities MODEL MEDICA-R 200 Make-up rate @15°C 200 l/hr Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2) Particles 0.2 m filter Silica <0.05 mg/l Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures Feedwater Requirement: Source: Tap water as detailed below Conductivity: <1000 S/cm Contaminant: Measure: Range: Pretreatment: Calcium: Ca ppm as CaCO3 <250 None3 >250 Softener or use very low RO recovery3 Free chlorine: Cl2ppm <0.1 None 0.1 0.5 20 inch carbon block >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm Chloramine: Cl2 ppm <0.1 None 0.1 0.5 20 inch high efficiency carbon (5) >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm Silica: SiO2 ppm <30 None >30 20 inch cartridge depth filter or use very low RO recovery (4) Fouling index: FI <10 None 10 to 20 20 inch cartridge depth filter >20 Back washable media filter with a minimum flow rate of 20 l/min Iron/manganese: Fe/Mn ppm <0.05 None >0.05 20 inch cartridge depth filter (5) >0.1 Back-washable Fe filter (6) Organics: TOC ppm C <2 None 2 to 3 20 inch carbon block (4) - >3 Cylinder of carbon sized correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) - Flowrate: (requirement at 15°C) 20 l/min Drain requirements: (gravity fall with air gap) 45 l/min Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) Must include: Installation, Commissioning, Training Electrical Requirements Mains Input: 115V, 60Hz System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA Electrical protection rating 20 amps Noise level during recirculation <70dBA ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. -The floor drain must be a minimum of 3" and meet all applicable building codes and system requirements -Actual Unit measurement 32" Wide x35"Deep x72"High VA Chesapeake Community Based Outpatient Clinic (CBOC) Chesapeake HCC1 Page 10 of 10 - - - - Qty: 1 - Finishes/Options - Image PATHOLOGY AND LABORATORY LAB-C1012(1) Department, Room, Quantity

Contact Information

Contracting Office Address

  • 100 EMANCIPATION DR
  • HAMPTON , VA 23667
  • USA

Primary Point of Contact

Secondary Point of Contact





History