General Information
- Contract Opportunity Type: Solicitation (Original)
- Original Published Date: May 02, 2023 02:26 pm CDT
- Original Date Offers Due: May 05, 2023 05:00 pm CDT
- Inactive Policy: 15 days after date offers due
- Original Inactive Date: May 20, 2023
- Initiative:
- None
Classification
- Original Set Aside:
- Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
- NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
- Place of Performance: Lemont , IL 60439USA
Description
Please provide a quote for Attocube Motion & Sensing precision engineering components OR EQUILVALENT:
1. Item No. 1012156, Quantity - 2, Delete standard UHV and RT fiber cables FLEX Standard sensor head M15.5/F40 made from tanium with focusing optics. Focal length: 40 mm. Incl. one Al coated mirror (Ø 9mm). For applications under UHV conditions.
2. Item No. 1012156, Quantity - 2 each, Delete standard UHV and RT fiber cables FLEX Standard sensor head M15.5/F40 made from tanium with focusing optics.
3. Item No. 1012162, Quantity - 2 each, Delete standard UHV and RT fiber cables Long range sensor head M12/C7.6 made from tanium with collimating optics. Spot size: 7.6 mm. For applications under UHV conditions.
4. Item No. 1010132, Quantity - 6 each, Environmental conditions: UHV Connectors: FC/PC to FC/APCb, Length: 1.5 m, Diameter: 3 mm armor.
5. Item No. 1010132, Quantity - 6 each, Environmental conditions: ambient Connectors: FC/APC to SC/APC, Length: 10 m, Diameter: 3 mm.
6. Item No. 1012156, Quantity - 3 each, Delete standard HV and RT fiber cables Sensor head M15.5/F55 made from tanium with focusing optics. Focal length: 74 +-5mm, estimate. For applications under high vacuum conditions (incl. fiber). incl. Al-coated mirror (Ø 9mm).
7. Item No. 1012156, Quantity - 2 each, Delete standard HV and RT fiber cables Sensor head M15.5/F50 made from tanium with focusing optics. Focal length: 62 +-5mm, estimate For applications under high vacuum conditions (incl. fiber). incl. Al-coated mirror (Ø 9mm).
8. Item No. 1012158, Quantity - 1 each, Delete standard HV and RT fiber cables sensor head M12/C1.6 made from tanium with collimating optics. Spot size: 1.6 mm. Incl. one Al coated mirror (Ø 9mm). For applications under low temperature and/or high vacuum conditions.
9. Item No. 1021202, Quantity - 1 each, Stainless steel Fomblin VAC3 fluorinated grease Tip/Tilt adjustable optical mount with M12 internal thread to screw sensorheads Material: Stainless steel & Fomblin VAC3 grease (HV/UHV compatible) 3 adjusting screws with 0.15 mm pitch 1 screw for fixation.
10. Item No. 1010132, Quantity - 6 each, Environmental conditions: HV Connectors: FC/PC to FC/APC Length: 1.5 m Diameter: 3 mm armor.
11. Item No. 1010132, Quantity - 6 each, Environmental conditions: ambient Connectors: FC/APC to SC/APC Length: 10 m Diameter: 3 mm
12. Item No. 1012156, Quantity - 2 each, Delete standard RT fiber cable Sensor head M15.5/F100 made from tanium with focusing optics. Focal length: 144.6+-0.5mm For applications under ambient conditions incl. Al-coated mirror (Ø 9mm)
13. Item No. 1012156, Quantity - 1 each, Delete standard RT fiber cable Sensor head M15.5/F135 made from tanium with focusing optics. Focal length: 206.2 +-5mm For applications under ambient conditions incl. Al-coated mirror (Ø 9mm).
14. Item No. 1010132, Quantity - 3 each, Environmental conditions: ambient Connectors: FC/PC to SC/APC Length: 10 m Diameter: 3 mm